HOME | Products | Inxpect Rader Saferty system

3D Radar Safety System

 

 
Inxpect Safety Radar  System

 
 

 

1. Inxpect Safety Radar:
The only radar certified for Safety Radar Equipment is designed to monitor dangerous areas in industrial environments and is intended for full body detection and protection
● IEC 62061 SIL2
● EN ISO 13849 PLd
● Category 2 - 3 (depending on model)

2.System architecture

Safety system based on radar technology to monitor and prevent the access to dangerous areas of a machinery. It is composed of a CONTROLLER and up to six SENSORS

 
 3.Certified safety functions
●Access protection:
prevents access to dangerous areas, switching to safe state
when the operator enters Restart prevention: prevents unexpected starting or restarting of the machinery as long as the operator remains in the dangerous area
●Restart can be:
Automatic, Safe-Manual or Manual.
●Anti-collision: 
in case of moving machinery to avoid collision both with operator and other machinery and also with overhead structures or suspended loads

4.RESISTANT TO DISTURBANCES
Optical devices often fail due to dust, smoke,water or waste generated by the production process. Inxpect Smart sensor reduces false alarms and increases productivity.
Inxpect Smart Sensors are immune not only to light, smoke and debris, but also to rain (rainfall rate up to 45 mm/h).
Inxpect works where optical sensors stop.High safety without compromising productivity.
5.Inxpect Safety Radar system is flexible, modular and scalable
Inxpect Safety Radar systems are composed of a control unit and up to six smart radar sensors: high flexibility,from simple to complex scenarios.
Configuring the system is quick and easy, thanks to the user friendly Safety Application.

 




 
 
*Type B control units: Low profile enclosure, SD card for backup and restore
● Safety Fieldbus: Profisafe FSoE
● Other protocols: ProfiNet, ModBus
● Four Output Signal Switching Devices
○ Safety Output: two dual-channel safety OSSDs.
○ Four Auxiliary Output: to configure restart
feedback signal, fault or muting status
● Two digital inputs: double channel to
configure muting signal, emergency stop
signal, restart signal
● Configuration options
USB: local configuration
Ethernet: remote configuration and
management protected by industry standard
cyber-security protocol
● Multiple and dynamic Configuration
○ digital input: up to four configurations
○ fieldbus: up to 32 configurations
● Muting function available

 

Dimention


 

Option

 

 

Case